TECHNICAL-LEGAL EXPERT REPORT TEMPLATE – Judicial Expert in Construction



(Art. 335.1 LEC – Official Judicial Expertise)
Record:[Procedure number / Internal reference]
Inspection dateon-site:[dd/mm/yyyy]
Report issue date:[dd/mm/yyyy]
Appointed/party expert:[Name, ID, member number if applicable]
Name of expert: Aurelio Tamarit Blay
DNI:[XXXXXXXX-X]
Member no.:[Ex. No. COAAT-XXXXX / not mandatory for party experts]
Accredited qualification:Technical Engineer of Public Works (ETS of Civil Engineers, Canals and Ports).
Specialty: Judicial Expertise in Construction, Real Estate and Naval.
Contact:clients@aureliotamarit.es | +34 662 221 582
Professional address:[Address in Valencia, with RGPD applied]


🔹 I. BACKGROUND AND PURPOSE OF THE REPORT

In compliance with the order made by[Name of client / Lawyer / Court], and in accordance with the provisions of articles 335 et seq. of the Civil Procedure Law, this document is issuedindependent technical expert report, in order to:

Diagnose the origin and mechanism of the humidity observed in the single-family home located in [anonymized address: “residential area, Benidorm, Alicante”],
determine if its cause is attributable to construction defects, lack of maintenance or external factors,
and evaluate compliance with current technical regulations (CTE, EHE-08, ITC-01).


🔹 II. METHODOLOGY USED

A protocol has been followed based on:

  • Visual inspectionon-site(day [date], time [time], weather conditions: [raining / dry / 48h without rain])
  • Measurement with calibrated equipment (annual certificates, no. [XXX]):
  • FLIR E8-XT thermocamera (resolution 320×240, precision ±2 °C)
  • Gann GMH 3810 Resistance Hygrometer (range 0–100% RH, accuracy ±2%)
  • HD industrial rigid endoscope with recording (Ø 6 mm, length 1 m)
  • Document analysis: basic distribution plans (provided by property), deed of new construction (if applicable), repair history.
  • Applied regulations:
  • CTE DB-HS 3: Protection against humidity
  • EHE-08, art. 32.4: Durability in elements exposed to environmental agents
  • ITC-01 of the CTE: Pathologies due to differential movements
  • UNE-EN 13183-1:2002: Moisture measurement in wood and porous materials
  • RD 235/2013: Energy Efficiency Certificate (relation to pathologies)

🔹 III. PROVEN FACTSON SITE

Inspected item Technical finding objective test
Attached party wall (NS) Double sheet of hollow brick without ventilated chamber or vapor barrier Endoscopy: water accumulated in the interleaf (attached video, min 2:15)
Upper crowning Cracked mortar, lack of water-repellent finish Georeferenced photography + GPS (lat/lon)
Leaking area (living room) Surface humidity in plaster > 25% RH Measurement with hygrometer (record: 26.3% at point A, 28.1% at point B)
Adjacent vertical wall Abnormal thermal pattern (difference ≥ 6 °C vs. ambient) Thermogram (attached): blue zone (8.2 °C) on a background of 16.4 °C
Bottom slab (slab) Efflorescence stains and coating peeling Visual sample + macroscopic analysis of soluble salts

Preliminary conclusion: The water does not come from the roof or from installations, but ratherpenetrates through the deficient crown and travels horizontally within the wall, filtering into the forging by capillarity.


🔹 IV. TECHNICAL ANALYSIS-FORGENSE

A. Failure mechanism

  1. Phase 1 – Entry: Rainwater penetrates through cracks in the crown (absence of elastic joint).
  2. Phase 2 – Transportation: The water descends by capillarity in the core of the double sheet wall (absence of water-repellent barrier → violationCTE DB-HS 3.2).
  3. Phase 3 – Lateral diffusion: Upon reaching the slab (critical construction node), the water spreads horizontally across the plaster-slab interface.
  4. Phase 4 – Manifestation: Visible leaks in ceiling + stains on vertical wall → symptomsnon-gravitational descenders.

B. Technical responsibility (according to jurisprudential doctrine)

  • STS 456/2022: “The mere existence of moisture does not imply liability, but it does when a construction defect is demonstrated that violates mandatory regulations”.
  • In this case,three objective breaches converge:
  1. Lack of water-repellent finish (CTE DB-HS 3)
  2. Absence of moisture barrier on walls in contact with the ground/open air (EHE-08 Art. 32.4)
  3. Cracks due to unforeseen movements (ITC-01)

Pre-existing cause of writingif the work is <10 years (ten-year term, art. 1,591 CC).


🔹 V. EXPERT CONCLUSIONS (Art. 340.2 LEC)

  1. The origin of the humidity is a serious construction deficiency in the party wall, not attributable to lack of reasonable use or maintenance by the owner.
  2. The filtration mechanism is validated by objective tests(thermography, hygrometry, endoscopy), documented and dated.
  3. The solution is through structural intervention, non-palliative: crown sealing, water-repellent injection and passive ventilation.
  4. The report meets the formal requirements of art. 340 LEC: signature, identification of the expert, methodology, proven facts and reasoned conclusions.

🔹 VI. INTERVENTION PROPOSAL (Optional – for mediation or execution)

Performance Reference standard Estimated term
Crown sealing with type II water-repellent mortar + silicone joint CTE DB-HS 3.2 2 days
Microinjection of flexible acrylic resin (pressure 15–20 bar) UNE 41790:2020 1 day
Upper passive ventilation (grid Ø 80 mm) DB-HE 1 (air renewal) 0.5 days
Removal of affected coatings + anti-fungal treatment Royal Decree 163/2009 (biological risks) 2 days

Indicative estimated cost (without VAT): €3,800–4,500 (depending on accessibility).

Note: quote closed after detailed measurement.


🔹 VII. ATTACHED DOCUMENTATION (Annexes)

  1. Annex 1: Georeferenced and dated photographs (12 images)
  2. Annex 2: Infrared thermograms with temperature scale and legend
  3. Annex 3: Hygrometry records (signed and with calibrated equipment number)
  4. Annex 4: Video capture of the endoscope (min 1:45–3:20, critical zone)
  5. Annex 5: Technical sketch of the pathology (1:50 scale, with dimensions and details)
  6. Annex 6: Equipment calibration certificates (current)
  7. Annex 7: Photocopy of the DNI and certification of the expert

🔹 VIII. DECLARATION OF IMPARTIALITY AND CONFIDENTIALITY

The undersigned declares under his/her responsibility that:

  • He has no personal, professional or economic relationship with any of the parties involved.
  • This report is issued withtechnical independence and objectivity, without external influence.
  • The data processed complies with theGDPR (EU 2016/679) and the Organic Law 3/2018.
  • The report is delivered underprofessional secret(art. 24 LEC and art. 540 LECrim if applicable).

🔹 IX. SIGNATURE OF THE EXPERT

“In [City], on [date], being [time] hours, I proceed to sign this expert report as a sign of agreement with its contents.”

handwritten signature ![Signature](space for scanned signature)
Name: Aurelio Tamarit Blay
DNI: [XXXXXXXX-X]
Qualified electronic signature (optional): eIDAS-QES-[hash SHA-256]
[Certificado FNMT / ACCV]

Download here



Source link